Find out more

BS 8414

This large-scale system test that mimics a fire breaking out of a window on a high rise building and exposing an external cladding system to a severe fire.  It is solely intended to give an indication of fire spread across or within an external cladding system.  The test duration of exposure to heat and flame is 30 minutes.

BS 8414-2 ‘Fire performance of external cladding systems - Test method for non-load bearing external cladding systems fixed to, and supported by, a structural steel frame’ does not test the individual component parts of a rainscreen cladding system in isolation (i.e. the fixings, fire breaks, cavities or insulation), but rather how the full build up behaves under fire conditions.  Typically, we see this in new high rise builds with modern building materials.

Once the test is completed and cooled, all components are inspected and reported.
Contact us

LPS 1181

This a large-scale reaction to fire system test (commonly known as ‘The Garage Test') that mimics a fire breaking out inside a building and exposing a cladding system to a fire, the test duration of exposure to flame is 15 minutes.

The standard, ‘LPS 1181 Part 1: Issue 1.2 – Requirements and tests for built up cladding and sandwich panel systems for use as external envelope of buildings’ does not test the individual component parts of a cladding system in isolation (i.e. the fixings, fire breaks, cavities or insulation), but rather determines the fire growth performance of the cladding products used; internal lining, insulation and external surface.  Once the test is completed all components are inspected.  To ascertain their response in contributing to a fire which it is exposed by its own decomposition.
Contact us

Radiant Roof (T4)

Radiant roof test equipment is used to determine the performance of roof products and systems to external fire exposure.  There are primarily two standards used; one British standard and one European Technical Specification;
BS 476-3:2004 – External fire exposure to roofs

DD CEN/TS 1187:2012 – Test methods for external fire exposure to roofs
Both include staged test methods incorporating burning brands, wind and supplementary radiant heat.  The testing procedures determine the ability of a roofing product and/or system to resist fire and to examine how it would react to a nearby fire.  In particular, tests consider the transference potential from outside the building itself, and the likelihood of a fire penetrating the roof and spreading across its surface.  Dependent upon test results, a minimum 3 parallel tests are performed.
TS 1187 Test Method 4 is commonly known as the T4 (or BROOFT4) test.
Contact us

SBI

A method of testing that is used to determine the reaction to fire behaviour when a construction product it is subject to thermal attack by a single heat source;  BS EN 13823:2020 Reaction to fire tests for building products. Building products excluding floorings exposed to the thermal attack by a single burning item.

The test is relevant for Euroclass’ A1, A2, A2L, B, BL, C, CL, D and DL. in accordance with BS EN 13501-1. The product being tested is mounted on a trolley and positioned in a frame beneath an exhaust system. As the item is exposed to flame, the exhaust system collects combustion gases for analysis and the amount of smoke produced is measured. The flame propagation and occurrence of burning particles and droplets are also identified in the specimen’s burning behaviour.
Contact us

Bomb Calorimeter

BS EN ISO 1716:2018 Reaction to fire tests for products – Determination of gross heat of combustion (calorific value) is the test method used for the determination of the gross heat of combustion of products at a constant volume in a bomb calorimeter.

Determination of the heat of combustion of a material (substantial and non-substantial components of a product) is required in accordance with BS EN 13501-1 Euroclass’ A1 and A2, and floorings to classes A1fl and A2fl. In this test, a test specimen of specified mass is combusted completely under standardised conditions, at constant volume, in an oxygen atmosphere, in a high-pressure calorimetric bomb. The calorific value determined under these conditions is calculated on the basis of the observed temperature rise, taking account of heat losses and the latent heat of vaporisation of water. This test determines an absolute combustion value of the product. Dependent upon test results, a minimum 3 parallel tests are performed.
Contact us

Non-combustibility

Performance of construction products and materials in accordance with BS EN ISO 1182, evaluates the non-combustible properties of construction materials. The test is included in the BS EN 13501-1 fire classification standard for classifications A1, A2 (construction products, excluding flooring), A1fl, A2fl (flooring products), A1L, and A2L (linear pipe thermal insulation products). During the test, the specimen is placed in a furnace and possible burning events are monitored along with any temperature variation.
Contact us

Ignitability Needle Flame

Performance of construction products and materials in accordance with BS EN ISO 11925-2, measures the ignitability of a sample when subjected to direct impingement of flame. It is relevant to material classes B, C, D and E in accordance with BS EN 13501-1.
Contact us